Sweden Building 05K0111
Start Page
General Information
Year of construction | 1900 |
---|---|
Category | Office |
Boundaries | Several buildings |
Ownership Category | Private company |
Total floor area (BRA), m2 | 1419.0 |
OID, m2 | 1443.0 |
Interior height, m | 3.0 |
Year of construction 1 (taxation year) | 1950 |
Year of construction 2 (Year of construction) | 1900 |
County | Gävleborg County, Sweden |
Mean annual temperature during the calculation period[1] | 5.75833333333 |
Mean annual temperature at the site | 5.2 |
Start of the period (first day of the month) | 2004/01/01 |
End of the period (last day of the month) | 2004/12/01 |
References | Swedish Energy Agency[2] |
Areas by category, m2 (Gross Floor Area)
- Offices | 1419.0
|
---|---|
Total | 1419.0 |
References | Swedish Energy Agency[2] |
Purchased energy for the period [MWh/year]
Electricity, total | 65.3 |
---|---|
District heating | 184.33 |
Oil-fired boiler | 0.0 |
Natural gas | 0.0 |
Town gas | 0.0 |
Digester / landfill gas | 0.0 |
Pellets | 0.0 |
Wood chips | 0.0 |
Logs | 0.0 |
District cooling | 0.0 |
Other | 0.0 |
Total | 249.63 |
References | Swedish Energy Agency[2] |
Purchased energy, normal year [MWh/year]
Electricity, total | 65.3 |
---|---|
District heating | 197.075726872 |
Oil-fired boiler | 0.0 |
Natural gas | 0.0 |
Town gas | 0.0 |
Digester / landfill gas | 0.0 |
Pellets | 0.0 |
Wood chips | 0.0 |
Logs | 0.0 |
District cooling | 0.0 |
Other | 0.0 |
Total | 262.375726872 |
References | Swedish Energy Agency[2] |
Purchased energy per area [kWh/m2]
Electricity, total | 46.0183227625 |
---|---|
Electric heating | 0.0 |
Other electricity | 46.0183227625 |
District heating | 138.883528451 |
Oil-fired boiler | 0.0 |
Natural gas | 0.0 |
Town gas | 0.0 |
Digester / landfill gas | 0.0 |
Pellets | 0.0 |
Wood chips | 0.0 |
Logs | 0.0 |
District cooling | 0.0 |
Other | 0.0 |
Total | 184.901851214 |
Breakdown of electricity use [kWh/m2]
Electric heating | 0.0 |
---|---|
Heat pumps | 0.0 |
Refrigeration | 0.845665961945 |
Heat pumps used for cooling | 0.0704721634954 |
Pumps | 3.18765247156 |
Fans | 9.16913319239 |
Lighting | 13.9715574348 |
PCs | 4.28414376321 |
Large computers / servers | 2.46652572234 |
Printers | 1.5503875969 |
Copiers | 3.38266384778 |
Air compressors | 0.0 |
Small kitchens / coffee rooms | 1.64059196617 |
Large kitchens | 0.0 |
Elevators | 0.0 |
Laundry | 0.0 |
Electric engine heaters | 0.887949260042 |
Circulation fans | 0.0 |
Miscellaneous | 5.5200008054 |
Total | 46.976744186 |
References | Swedish Energy Agency[2] |
Breakdown of electricity use [%]
Electric heating | 0.0 |
---|---|
Heat pumps | 0.0 |
Refrigeration | 1.800180018 |
Heat pumps used for cooling | 0.1500150015 |
Pumps | 6.7855968454 |
Fans | 19.5184518452 |
Lighting | 29.7414341434 |
PCs | 9.1197119712 |
Large computers / servers | 5.25052505251 |
Printers | 3.300330033 |
Copiers | 7.20072007201 |
Air compressors | 0.0 |
Small kitchens / coffee rooms | 3.49234923492 |
Large kitchens | 0.0 |
Elevators | 0.0 |
Laundry | 0.0 |
Electric engine heaters | 1.8901890189 |
Circulation fans | 0.0 |
Miscellaneous | 11.750496764 |
Total | 100.0 |
References | Swedish Energy Agency[2] |