Sweden Building 05K0084
Start Page
General Information
Year of construction | 1880 |
---|---|
Category | Office |
Boundaries | One building |
Ownership Category | Private company |
Total floor area (BRA), m2 | 1065.0 |
OID, m2 | 1115.0 |
Interior height, m | 3.0 |
Year of construction 1 (taxation year) | 1929 |
Year of construction 2 (Year of construction) | 1880 |
County | Västra Götaland County, Sweden |
Mean annual temperature during the calculation period[1] | 7.30833333333 |
Mean annual temperature at the site | 6.3 |
Start of the period (first day of the month) | 2004/01/01 |
End of the period (last day of the month) | 2004/12/01 |
References | Swedish Energy Agency[2] |
Areas by category, m2 (Gross Floor Area)
- Offices | 1065.0
|
---|---|
Total | 1065.0 |
References | Swedish Energy Agency[2] |
Purchased energy for the period [MWh/year]
Electricity, total | 77.61 |
---|---|
District heating | 130.0 |
Oil-fired boiler | 0.0 |
Natural gas | 0.0 |
Town gas | 0.0 |
Digester / landfill gas | 0.0 |
Pellets | 0.0 |
Wood chips | 0.0 |
Logs | 0.0 |
District cooling | 0.0 |
Other | 0.0 |
Total | 207.61 |
References | Swedish Energy Agency[2] |
Purchased energy, normal year [MWh/year]
Electricity, total | 77.61 |
---|---|
District heating | 136.866552316 |
Oil-fired boiler | 0.0 |
Natural gas | 0.0 |
Town gas | 0.0 |
Digester / landfill gas | 0.0 |
Pellets | 0.0 |
Wood chips | 0.0 |
Logs | 0.0 |
District cooling | 0.0 |
Other | 0.0 |
Total | 214.476552316 |
References | Swedish Energy Agency[2] |
Purchased energy per area [kWh/m2]
Electricity, total | 72.8732394366 |
---|---|
Electric heating | 0.0 |
Other electricity | 72.8732394366 |
District heating | 128.513194663 |
Oil-fired boiler | 0.0 |
Natural gas | 0.0 |
Town gas | 0.0 |
Digester / landfill gas | 0.0 |
Pellets | 0.0 |
Wood chips | 0.0 |
Logs | 0.0 |
District cooling | 0.0 |
Other | 0.0 |
Total | 201.386434099 |
Breakdown of electricity use [kWh/m2]
Electric heating | 0.0 |
---|---|
Heat pumps | 0.0 |
Refrigeration | 1.34585289515 |
Heat pumps used for cooling | 0.093896713615 |
Pumps | 2.89410630449 |
Fans | 17.0822937626 |
Lighting | 21.2273239437 |
PCs | 11.8610328638 |
Large computers / servers | 0.0 |
Printers | 0.698591549296 |
Copiers | 1.12676056338 |
Air compressors | 0.0 |
Small kitchens / coffee rooms | 2.6103286385 |
Large kitchens | 0.0 |
Elevators | 4.54084507042 |
Laundry | 0.0 |
Electric engine heaters | 0.169014084507 |
Circulation fans | 0.0 |
Miscellaneous | 9.48610384529 |
Total | 73.1361502347 |
References | Swedish Energy Agency[2] |
Breakdown of electricity use [%]
Electric heating | 0.0 |
---|---|
Heat pumps | 0.0 |
Refrigeration | 1.84020199427 |
Heat pumps used for cooling | 0.128386185646 |
Pumps | 3.95714881793 |
Fans | 23.3568402326 |
Lighting | 29.0243933753 |
PCs | 16.2177429709 |
Large computers / servers | 0.0 |
Printers | 0.955193221209 |
Copiers | 1.54063422776 |
Air compressors | 0.0 |
Small kitchens / coffee rooms | 3.56913596097 |
Large kitchens | 0.0 |
Elevators | 6.20875593786 |
Laundry | 0.0 |
Electric engine heaters | 0.231095134164 |
Circulation fans | 0.0 |
Miscellaneous | 12.9704719415 |
Total | 100.0 |
References | Swedish Energy Agency[2] |