Sweden Building 05K0083
Start Page
General Information
Year of construction | 1929 |
---|---|
Category | Office |
Boundaries | One building |
Ownership Category | Private company |
Total floor area (BRA), m2 | 2866.0 |
OID, m2 | 3000.0 |
Interior height, m | 2.5 |
Year of construction 1 (taxation year) | 2004 |
Year of construction 2 (Year of construction) | 1929 |
County | Skåne County, Sweden |
Mean annual temperature during the calculation period[1] | 8.65833333333 |
Mean annual temperature at the site | 8.2 |
Start of the period (first day of the month) | 2004/01/01 |
End of the period (last day of the month) | 2004/12/01 |
References | Swedish Energy Agency[2] |
Areas by category, m2 (Gross Floor Area)
- Offices | 2866.0
|
---|---|
Total | 2866.0 |
References | Swedish Energy Agency[2] |
Purchased energy for the period [MWh/year]
Electricity, total | 136.0 |
---|---|
District heating | 245.0 |
Oil-fired boiler | 0.0 |
Natural gas | 0.0 |
Town gas | 0.0 |
Digester / landfill gas | 0.0 |
Pellets | 0.0 |
Wood chips | 0.0 |
Logs | 0.0 |
District cooling | 0.0 |
Other | 0.0 |
Total | 381.0 |
References | Swedish Energy Agency[2] |
Purchased energy, normal year [MWh/year]
Electricity, total | 136.071028037 |
---|---|
District heating | 264.506074766 |
Oil-fired boiler | 0.0 |
Natural gas | 0.0 |
Town gas | 0.0 |
Digester / landfill gas | 0.0 |
Pellets | 0.0 |
Wood chips | 0.0 |
Logs | 0.0 |
District cooling | 0.0 |
Other | 0.0 |
Total | 400.577102804 |
References | Swedish Energy Agency[2] |
Purchased energy per area [kWh/m2]
Electricity, total | 47.4776790082 |
---|---|
Electric heating | 0.279134682484 |
Other electricity | 47.1985443257 |
District heating | 92.2910239938 |
Oil-fired boiler | 0.0 |
Natural gas | 0.0 |
Town gas | 0.0 |
Digester / landfill gas | 0.0 |
Pellets | 0.0 |
Wood chips | 0.0 |
Logs | 0.0 |
District cooling | 0.0 |
Other | 0.0 |
Total | 139.768703002 |
Breakdown of electricity use [kWh/m2]
Electric heating | 0.279134682484 |
---|---|
Heat pumps | 0.0 |
Refrigeration | 2.21535462289 |
Heat pumps used for cooling | 0.0 |
Pumps | 2.03280729738 |
Fans | 8.95852856146 |
Lighting | 22.4662526169 |
PCs | 0.753035589672 |
Large computers / servers | 6.10607117934 |
Printers | 0.0 |
Copiers | 1.74459176553 |
Air compressors | 0.0 |
Small kitchens / coffee rooms | 1.8318213538 |
Large kitchens | 0.0 |
Elevators | 0.610607117934 |
Laundry | 0.0 |
Electric engine heaters | 0.0 |
Circulation fans | 0.0 |
Miscellaneous | 0.454691234949 |
Total | 47.4528960223 |
References | Swedish Energy Agency[2] |
Breakdown of electricity use [%]
Electric heating | 0.588235294118 |
---|---|
Heat pumps | 0.0 |
Refrigeration | 4.6685340803 |
Heat pumps used for cooling | 0.0 |
Pumps | 4.28384243697 |
Fans | 18.8787815126 |
Lighting | 47.3443235294 |
PCs | 1.58691176471 |
Large computers / servers | 12.8676470588 |
Printers | 0.0 |
Copiers | 3.67647058824 |
Air compressors | 0.0 |
Small kitchens / coffee rooms | 3.86029411765 |
Large kitchens | 0.0 |
Elevators | 1.28676470588 |
Laundry | 0.0 |
Electric engine heaters | 0.0 |
Circulation fans | 0.0 |
Miscellaneous | 0.958194911298 |
Total | 100.0 |
References | Swedish Energy Agency[2] |