Sweden Building 05K0097

Jump to: navigation, search

Start Page

General Information

Year of construction 2002
Category Office
Boundaries One building
Ownership Category Local community owner
Total floor area (BRA), m2 2480.0
OID, m2 2550.0
Interior height, m 3.0
Year of construction 1 (taxation year) 2002
Year of construction 2 (Year of construction) 2002
County Dalarna County, Sweden
Mean annual temperature during the calculation period[1] 5.175
Mean annual temperature at the site 3.7
Start of the period (first day of the month) 2004/01/01
End of the period (last day of the month) 2004/12/01
References Swedish Energy Agency[2]

Areas by category, m2 (Gross Floor Area)

- Offices 2480.0














Total 2480.0
References Swedish Energy Agency[2]

Purchased energy for the period [MWh/year]

Electricity, total 415.0
District heating 211.0
Oil-fired boiler 0.0
Natural gas 0.0
Town gas 0.0
Digester / landfill gas 0.0
Pellets 0.0
Wood chips 0.0
Logs 0.0
District cooling 0.0
Other 0.0
Total 626.0
References Swedish Energy Agency[2]

Purchased energy, normal year [MWh/year]

Electricity, total 415.0
District heating 234.0
Oil-fired boiler 0.0
Natural gas 0.0
Town gas 0.0
Digester / landfill gas 0.0
Pellets 0.0
Wood chips 0.0
Logs 0.0
District cooling 0.0
Other 0.0
Total 649.0
References Swedish Energy Agency[2]

Purchased energy per area [kWh/m2]

Electricity, total 167.338709677
Electric heating 0.0
Other electricity 167.338709677
District heating 94.3548387097
Oil-fired boiler 0.0
Natural gas 0.0
Town gas 0.0
Digester / landfill gas 0.0
Pellets 0.0
Wood chips 0.0
Logs 0.0
District cooling 0.0
Other 0.0
Total 261.693548387

Breakdown of electricity use [kWh/m2]

Electric heating 0.0
Heat pumps 0.0
Refrigeration 37.9032258065
Heat pumps used for cooling 2.01612903226
Pumps 20.4080645161
Fans 14.3525345622
Lighting 29.7766129032
PCs 5.32258064516
Large computers / servers 41.3709677419
Printers 0.607096774194
Copiers 2.17741935484
Air compressors 0.0
Small kitchens / coffee rooms 2.95967741935
Large kitchens 0.0
Elevators 0.181451612903
Laundry 0.00100806451613
Electric engine heaters 4.03225806452
Circulation fans 7.06451612903
Miscellaneous 12.2780702765
Total 180.451612903
References Swedish Energy Agency[2]

Breakdown of electricity use [%]

Electric heating 0.0
Heat pumps 0.0
Refrigeration 21.004647837
Heat pumps used for cooling 1.11726850197
Pumps 11.3094386843
Fans 7.95367485571
Lighting 16.5011619592
PCs 2.94958884519
Large computers / servers 22.9263496604
Printers 0.336431891312
Copiers 1.20664998212
Air compressors 0.0
Small kitchens / coffee rooms 1.64015016089
Large kitchens 0.0
Elevators 0.100554165177
Laundry 0.000558634250983
Electric engine heaters 2.23453700393
Circulation fans 3.91490883089
Miscellaneous 6.80407898769
Total 100.0