Sweden Building 05K0096

From Open Energy Information

Start Page

General Information

Year of construction 1940
Category Office
Boundaries One building
Ownership Category Local community owner
Total floor area (BRA), m2 861.0
OID, m2 886.0
Interior height, m 3.0
Year of construction 1 (taxation year) 2004
Year of construction 2 (Year of construction) 1940
County Dalarna County, Sweden
Mean annual temperature during the calculation period[1] 3.275
Mean annual temperature at the site 3.7
Start of the period (first day of the month) 2004/11/01
End of the period (last day of the month) 2005/10/01
References Swedish Energy Agency[2]

Areas by category, m2 (Gross Floor Area)

- Offices 861.0








Total 861.0
References Swedish Energy Agency[2]

Purchased energy for the period [MWh/year]

Electricity, total 34.0
District heating 80.0
Oil-fired boiler 0.0
Natural gas 0.0
Town gas 0.0
Digester / landfill gas 0.0
Pellets 0.0
Wood chips 0.0
Logs 0.0
District cooling 0.0
Other 0.0
Total 114.0
References Swedish Energy Agency[2]

Purchased energy, normal year [MWh/year]

Electricity, total 34.0
District heating 88.1361888942
Oil-fired boiler 0.0
Natural gas 0.0
Town gas 0.0
Digester / landfill gas 0.0
Pellets 0.0
Wood chips 0.0
Logs 0.0
District cooling 0.0
Other 0.0
Total 122.136188894
References Swedish Energy Agency[2]

Purchased energy per area [kWh/m2]

Electricity, total 39.4889663182
Electric heating 0.0
Other electricity 39.4889663182
District heating 102.364911608
Oil-fired boiler 0.0
Natural gas 0.0
Town gas 0.0
Digester / landfill gas 0.0
Pellets 0.0
Wood chips 0.0
Logs 0.0
District cooling 0.0
Other 0.0
Total 141.853877926

Breakdown of electricity use [kWh/m2]

Electric heating 0.0
Heat pumps 0.0
Refrigeration 0.0
Heat pumps used for cooling 0.0
Pumps 4.54894225983
Fans 8.66019578563
Lighting 12.2880371661
PCs 3.06620209059
Large computers / servers 3.01974448316
Printers 0.261324041812
Copiers 1.50987224158
Air compressors 0.0
Small kitchens / coffee rooms 2.3112659698
Large kitchens 0.0
Elevators 0.574912891986
Laundry 0.0
Electric engine heaters 0.0
Circulation fans 0.0
Miscellaneous 3.24846938776
Total 39.4889663182
References Swedish Energy Agency[2]

Breakdown of electricity use [%]

Electric heating 0.0
Heat pumps 0.0
Refrigeration 0.0
Heat pumps used for cooling 0.0
Pumps 11.5195273109
Fans 21.9306722689
Lighting 31.1176470588
PCs 7.76470588235
Large computers / servers 7.64705882353
Printers 0.661764705882
Copiers 3.82352941176
Air compressors 0.0
Small kitchens / coffee rooms 5.85294117647
Large kitchens 0.0
Elevators 1.45588235294
Laundry 0.0
Electric engine heaters 0.0
Circulation fans 0.0
Miscellaneous 8.2262710084
Total 100.0
References Swedish Energy Agency[2]

References

  1. Swedish Meteorological and Hydrological Institute
  2. Swedish Energy Agency