Sweden Building 05K0055

Jump to: navigation, search

Start Page

General Information

Year of construction 1940
Category Office
Boundaries One building
Ownership Category Social housing company etc.
Total floor area (BRA), m2 11335.0
OID, m2 12278.0
Interior height, m 0.0
Year of construction 1 (taxation year) 1954
Year of construction 2 (Year of construction) 1940
County Stockholm County, Sweden
Mean annual temperature during the calculation period[1] 7.08333333333
Mean annual temperature at the site 6.6
Start of the period (first day of the month) 2004/11/01
End of the period (last day of the month) 2005/10/01
References Swedish Energy Agency[2]

Areas by category, m2 (Gross Floor Area)

- Offices 11335.0














Total 11335.0
References Swedish Energy Agency[2]

Purchased energy for the period [MWh/year]

Electricity, total 1454.0
District heating 842.0
Oil-fired boiler 0.0
Natural gas 0.0
Town gas 0.0
Digester / landfill gas 0.0
Pellets 0.0
Wood chips 0.0
Logs 0.0
District cooling 0.0
Other 0.0
Total 2296.0
References Swedish Energy Agency[2]

Purchased energy, normal year [MWh/year]

Electricity, total 1454.71309006
District heating 897.870605959
Oil-fired boiler 0.0
Natural gas 0.0
Town gas 0.0
Digester / landfill gas 0.0
Pellets 0.0
Wood chips 0.0
Logs 0.0
District cooling 0.0
Other 0.0
Total 2352.58369602
References Swedish Energy Agency[2]

Purchased energy per area [kWh/m2]

Electricity, total 128.338164099
Electric heating 0.88222320247
Other electricity 127.455940896
District heating 79.2122281393
Oil-fired boiler 0.0
Natural gas 0.0
Town gas 0.0
Digester / landfill gas 0.0
Pellets 0.0
Wood chips 0.0
Logs 0.0
District cooling 0.0
Other 0.0
Total 207.550392238

Breakdown of electricity use [kWh/m2]

Electric heating 0.88222320247
Heat pumps 0.0
Refrigeration 20.9001522546
Heat pumps used for cooling 1.54815942627
Pumps 4.90151717184
Fans 20.3374503749
Lighting 15.5107629884
PCs 5.95191883547
Large computers / servers 29.642699603
Printers 0.494044993383
Copiers 1.13365681517
Air compressors 0.0
Small kitchens / coffee rooms 1.06484340538
Large kitchens 14.6837229819
Elevators 0.661667401853
Laundry 0.0
Electric engine heaters 0.0
Circulation fans 0.116453462726
Miscellaneous 12.1078568196
Total 129.937129737
References Swedish Energy Agency[2]

Breakdown of electricity use [%]

Electric heating 0.678961590313
Heat pumps 0.0
Refrigeration 16.0848190944
Heat pumps used for cooling 1.19146808106
Pumps 3.77222213678
Fans 15.6517620607
Lighting 11.9371291484
PCs 4.58061436905
Large computers / servers 22.8131094345
Printers 0.380218490575
Copiers 0.872465643552
Air compressors 0.0
Small kitchens / coffee rooms 0.819506639507
Large kitchens 11.3006367092
Elevators 0.509221192735
Laundry 0.0
Electric engine heaters 0.0
Circulation fans 0.0896229299213
Miscellaneous 9.31824247937
Total 100.0
References Swedish Energy Agency[2]

References

  1. Swedish Meteorological and Hydrological Institute
  2. Swedish Energy Agency