Injectivity Test At Vale Hot Springs Area (Combs, Et Al., 1999)

Jump to: navigation, search
GEOTHERMAL ENERGYGeothermal Home

Exploration Activity: Injectivity Test At Vale Hot Springs Area (Combs, Et Al., 1999)

Exploration Activity Details
Location Vale Hot Springs Area
Exploration Technique Injectivity Test
Activity Date

Usefulness useful
DOE-funding Unknown

 
Notes
Analysis of the two injection tests performed at the exploration slimhole site during May, 1995 yielded estimates for the permeability-thickness product (transmissivity) kh of 0.25 and 0.23 Da-fi, based on pressure fall off after injection (see Section IV-a). Using the pressure buildup for the second test, a transmissivity of 0.610 Da-ft was estimated. These estimates are approximately an order of magnitude smaller than the kh values estimated for the nearby A-Alt well which was tested in 1994.

 
References