Abstract
Heat flow studies in the Coso Geothermal Area were conducted at China Lake, California. Temperature measurements were completed in nine of the heat flow boreholes. Temperatures were measured at five meter intervals from the ground surface to the deepest five meter interval. Subsequently, temperatures were remeasured two or three times in each borehole in order to demonstrate that equilibrium thermal conditions existed. The maximum difference in temperature, at any of the five meter intervals, was 0.03 deg C. Results from these boreholes, as well as from the other seven, indicate that the temperature data above 15 meters is useless for calculating the geothermal gradients. This is due to the effects of solar radiation at the surface of the earth.

Authors 
Combs and J.  








Published 
Publisher Not Provided, 2/28/1975





DOI 
Not Provided
Check for DOI availability: http://crossref.org



 

Citation

Combs, J.  . 2/28/1975. Heat flow studies, Coso Geothermal Area, China Lake, California. Technical report. (!) : .