Flow Test At Fenton Hill HDR Geothermal Area (Brown, 1995)

Jump to: navigation, search
GEOTHERMAL ENERGYGeothermal Home

Exploration Activity: Flow Test At Fenton Hill HDR Geothermal Area (Brown, 1995)

Exploration Activity Details
Location Fenton Hill HDR Geothermal Area
Exploration Technique Flow Test
Activity Date 1989 - 1990

Usefulness not indicated
DOE-funding Unknown

 
Exploration Basis
A series of brief flow tests were conducted on the Phase II reservoir between 1989 and 1990 leading up to the LTFT.
 
Notes
The rate of water loss steadily declined following an initial transient period of increased water storage within the Phase II reservoir. After 9 out of a total of 17 months of pressurization at 15 MPa above hydrostatic pressure, the rate of water loss from the Phase II reservoir approached a constant value of about 0.13 L/s, suggesting a transition to diffusional water loss from the spherical reservoir volume.