Distributed Generation Study/Matlink Farm

Jump to: navigation, search
Study Location Clymers, New York
Site Description Agricultural
Study Type Long-term Monitoring
Technology Internal Combustion Engine
Prime Mover Waukesha 145
Heat Recovery Systems Built-in
Fuel Biogas
System Installer Martin Machine
System Enclosure Outdoor
System Application Combined Heat and Power
Number of Prime Movers 1
Stand-alone Capability None
Power Rating 145 kW0.145 MW
145,000 W
145,000,000 mW
1.45e-4 GW
1.45e-7 TW
Nominal Voltage (V) 480
Heat Recovery Rating (BTU/hr) 1500000
Cooling Capacity (Refrig/Tons)
Origin of Controller 3rd Party Off-the-Shelf
Component Integration Customer Assembled
Start Date 2004/10/28
Monitoring Termination Date 2005/07/16
Primary Power Application Based Load
Secondary Power Application
Primary Heat/Cooling Application Other
Secondary Heat/Cooling Application
Capacity Factor .328
Availability 0
Electrical Efficiency (HHV)
Electrical Efficiency (LHV)
Highest Combustion Intake Air Temperature (F) 100°F310.928 K
37.778 °C
559.67 °R
Lowest Combustion Intake Air Temperature (F) 0°F255.372 K
-17.778 °C
459.67 °R
NOx Emissions Data Available No
CO Emissions Data Available No
12-Month Run Hours 4416
12-Month Energy Savings (USD)
System Cost (USD)
Report URL http://chp.nyserda.org/facilities/details.cfm?facility=38
Study Verified Yes