Distributed Generation Study/Harbec Plastics

Jump to: navigation, search
Study Location Ontario, New York
Site Description Industrial-Plastics Processing
Study Type Long-term Monitoring
Technology Microturbine
Prime Mover Capstone C30
Heat Recovery Systems Built-in
Fuel Natural Gas
System Installer Northern Development
System Enclosure Indoor
System Application Combined Heat and Power
Number of Prime Movers 25
Stand-alone Capability None
Power Rating 750 kW0.75 MW
750,000 W
750,000,000 mW
7.5e-4 GW
7.5e-7 TW
Nominal Voltage (V) 480
Heat Recovery Rating (BTU/hr) 3750000
Cooling Capacity (Refrig/Tons)
Origin of Controller Manufacturer-Integrated
Component Integration Factory Integrated
Start Date 2005/10/06
Monitoring Termination Date 1969/12/31
Primary Power Application Based Load
Secondary Power Application
Primary Heat/Cooling Application Space Heat and/or Cooling
Secondary Heat/Cooling Application Space Heat and/or Cooling
Capacity Factor .18
Availability 0
Electrical Efficiency (HHV) 20
Electrical Efficiency (LHV) 22
Highest Combustion Intake Air Temperature (F) 75°F297.039 K
23.889 °C
534.67 °R
Lowest Combustion Intake Air Temperature (F) 65°F291.483 K
18.333 °C
524.67 °R
NOx Emissions Data Available No
CO Emissions Data Available No
12-Month Run Hours 111454
12-Month Energy Savings (USD)
System Cost (USD)
Report URL http://chp.nyserda.org/facilities/details.cfm?facility=109
Study Verified Yes