Direct-Current Resistivity Survey At Stillwater Area (Laney, 2005)

From Open Energy Information

Exploration Activity: Direct-Current Resistivity Survey At Stillwater Area (Laney, 2005)

Exploration Activity Details
Location Stillwater Area
Exploration Technique Direct-Current Resistivity Survey
Activity Date
Usefulness useful
DOE-funding Unknown

 
Notes
Structural Controls, Alteration, Permeability and Thermal Regime of Dixie Valley from New-Generation Mt/Galvanic Array Profiling, Phillip Wannamaker. A new-generation MT/DC array resistivity measurement system was applied at the Dixie Valley thermal area. Basic goals of the survey are 1), resolve a fundamental structural ambiguity at the Dixie Valley thermal area (single rangefront fault versus shallower, stepped pediment; 2), delineate fault zones which have experienced fluid flux as indicated by low resistivity; 3), image the disposition of resistive, possible reservoir formations in the subsurface; and 4), from a generic standpoint, investigate the capability of fully sampled electrical data for resolving subsurface structure.


Additional References


<metadesc> Direct-Current Resistivity Survey At Stillwater Area (Laney, 2005): geothermal exploration activity. </metadesc>