Basic Specifications
Facility Name Alden Large Flume
Overseeing Organization Alden Research Laboratory, Inc
Hydrodynamic Testing Facility Type Flume
Length(m) 24.4
Beam(m) 6.1
Depth(m) 3.0
Water Type Freshwater
Cost(per day) $5000/week

Towing Capabilities
Towing Capabilities Yes
Maximum Velocity(m/s) 0.9
Maximum Velocity with Constriction(m/s) 3

Wavemaking Capabilities
Wavemaking Capabilities Yes
Maximum Wave Height(m) 0.0
Maximum Wave Height(m) at Wave Period(s) 0.0

Wave Period Range(s) 2.1
Current Velocity Range(m/s) 3.2
Programmable Wavemaking Yes
Wavemaking Description Wave generators not yet designed

Simulated Beach No

Channel/Tunnel/Flume
Channel/Tunnel/Flume Yes

Recirculating Yes

Wind Capabilities
Wind Capabilities Yes
Wind Velocity Range(m/s) Designed as needed
Other Characteristics Point measurement capability
Control and Data Acquisition
Description Differential pressure transducers, acoustic profiling, propeller meters, load cells, computer data acquisition systems.
Number of channels Designed as needed

Cameras Yes
Number of Color Cameras 2

Description of Camera Types fully-submersible; multiplexor for four cameras; digital recording from all cameras; digital handheld
Available Sensors Acceleration, Acoustics, Displacement, Flow, Power conversion effectiveness and generation, Pressure Range(psi), Thermal, Velocity, Vibration
Data Generation Capability
Real-Time Yes
Data Comparison to Computational Models Designed as needed
Integrated Display/Graphics Lab View, Test Point

Test Services
Test Services Yes
Utility Services Available 110 V to 480 V, 3 phase
On-Site fabrication capability/equipment Full on-site carpentry, machine, and instrumentation shops
Past Pertinent Test Experience Tested scaled models and full-scale hydrokinetic turbines for 3 developers
Special Characteristics
Special Characteristics Yes
Types of Co-located facilities Co-located fish holding facility is ideal for evaluating the impacts of generation devices on fish
Specializations, Capabilities, and Key
Facility Attributes Not Covered Elsewhere
This is a recirculating flume facility, so a constant velocity can be maintained indefinitely. This allows collection of a much greater amount of data than possible in tow tanks. Alden's biologists are highly experienced in assessing the impacts of generation devices on fish and the facilities allow for accurate testing with fish in a highly controlled environment.